Monitoring Program Data View Archives
Environmental monitoring of surface water (turbidity), air (dust and mercury vapor), and noise was conducted in accordance with the CMI work plan during the removal phases of the remediation program. Chemours is committed to sharing monitoring data (turbidity, dust, mercury vapor) collected during remedy implementation with the community. The graphs below contain data from the various monitoring locations around the project area.1. Wind Monitoring
Click Image to Enlarge
2. PM10 Particulate (Dust) Monitoring
Click Image to Enlarge
3. Mercury Vapor Monitoring
Click Image to Enlarge
Comments
Based on a review of the mercury vapor data, it appears there was a mercury meter malfunction at approximately 1545 at the downwind monitoring station (AM-2) causing the elevated reading as shown on the graph. None of the other 15-minute average mercury readings collected during this monitoring event were above the instrument’s detection limit of 0.05 µg/m3 and were below the threshold level of 0.31 µg/m3. Additionally, this elevated reading does not correlate to an elevated dust reading at AM-2 at the same time; further indicating that it was a meter malfunction. During this time period, the wind direction was away from AM-2 (i.e., wasn’t downgradient of any site-related activities such as dredging or sediment processing).
4. Turbidity Monitoring
Click Image to Enlarge